Baxter Flo-gard 6301 Service Manual Rating: 8,9/10 2303 votes

DescriptionRefurbished/ Recertified1 year warrantyThe Baxter 6301 Dual Channel Device is a volumetric infusion pump that is an industry standard in infusion technology. It is capable of delivering a wide variety of fluids over a broad range of infusion rates. As a Dual Channel pump it provides the clinician with the convenience of delivering fluids to 2 patients at once. The pump contains 2 linear peristaltic pump heads allowing it to simultaneously infuse 2 different solutions. Each pump head is independently programmable and permits infusion of primary and secondary medication programs. The secondary program automatically switches over to the primary program when secondary infusion is complete. Upon completion of the primary volume to be infused the pump automatically switches to a keep vein open rate.The pump uses standard IV administration sets that eliminates the need for costly disposable sets and reduces the potential for waste.

Flow Rate Range:Primary program: 1.0-99.9 mL/hr in 0.1 mL increments or 1-1999 mL/hr in 1 mL increments.Upper limit can be reduced by authorized service personnel.Secondary program: 1.0-99.9 mL/hr in 0.1 mL increments or 1-999 mL/hr in 1 mL incrementsVTBI Range: 1.0-99.9 mL in 0.1 mL increments or 1-9999 mL in 1 mL increments for both primary and secondary. Upper limit can be reduced by authorized service personnel.Ramp PDP Parameter Ranges:Total VTBI: 100-9,999 in 1 mL increments. Upper limit can be reduced by authorized service personnel.Delay Time: 00:00 – 08:00 hours in minute increments.Run Time: 01:00 – 16:00 hours in minute increments.Ramp Up: 00:00 to 45% of the Run Time, in minute increments.Ramp Down: 00-00 to the Run Time minus Ramp Up, in minute Increments.Air-in-Line Detection: Factory set to NORM, which causes the pump to alarm on air bubbles approximately 75 uL or larger. The MIN setting causes the pump to alarm on air bubbles approximately 50 ul or larger.

.Service Manual Chapter 1 Flo-Gard 6201 Volumetric Infusion Pump Product Code: 2M8063 BACK LIGHT ALARM PUMPING ALERT SILENCE TO ENSURE PROPER SET LOADING: NEXT TOT VOL STATUS Load tubing from bottom to top. CLEAR TOT VOL Ensure tubing.Baxter. This manual and any information contained within, may not be reproduced, distributed, or transmitted in any form, or by any means, for any purpose, without the express written permission of Baxter. To order additional copies of this manual, or other related manuals, contact your local Baxter Service Center.Routine Maintenance.Overview.

6-1 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.Removal/Replacement Procedures.8-1 Overview. 8-1 Preparation for Maintenance. 8-1 Tools and Test Equipment.8-1 Recording the Configuration Option Settings.8-2 Torque Specifications.

8-3 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.Replacement of Lithium Backup Battery.8-28 Tube Guide Shim Installation.8-29 LCD Cushion Installation. 8-30 Software Installation. 8-32 Routing of Internal Wiring. 8-33 Pole Clamp Tightening Instructions.8-34 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.Electrical Safety Tests.10-11 Ground Impedance. 10-11 Current Leakage.10-11 Accuracy Tests.10-12 Measurement by volume per time.10-12 Measurement incorporating VTBI option.10-12 One-Hour Accuracy Test. 10-13 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.Multiple Key Combinations.07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.Pump Base Plate Assembly.11-19 Figure 11-9 Safety/Slide Clamp Assembly (CCRA1006.A).11-22 Figure 11-10 Display PCB (CPWBN104.A).

11-23 Figure 11-11 Power Supply PCB (RDENC100.D). 11-24 Figure 11-12 CPU PCB (CPWBX104.A).11-25 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.Figure 13-21 LCD Drivers (part of Display Board).13-23 Figure 13-22 Liquid Crystal Displays (part of Display Board). 13-24 Figure 13-23 LED Lamps (part of Display Board). 13-25 Figure 13-24 Audible Alarm Board.13-26 viii FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.Figure 13-25 Backup Buzzer Board.13-27 Figure 13-26 Terminal Board.13-28 Figure 13-27 Accessories. 13-29 Figure 13-28 Pumphead Sensors.13-30 Figure 13-29 Front Panel Key Assignments. 13-31 Figure 13-30 Power Supply.13-32 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.Parts List - Safety/Slide Clamp Assembly.11-20 Table 11-10 Sensor PCB.

Baxter flo gard

11-26 Table 11-11 Parts List for Accessories and Options.11-29 Table 11-12 Parts List for Packaging Materials.11-29 Table D-1 Multiple Key Combinations.D-1 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL 07-19-B1-688.The pump operates on standard 115 VAC 60 Hz electrical power, or on its self-contained rechargeable battery. It is portable and has a panel lock-out feature to prevent tampering. It is designed for use with Baxter’s standard administration sets that contain an “s” as the last character of the code number, for example, 2C5537s.Any liability arising from the use of non-Baxter parts is assumed by the entity performing such work. Baxter’s warranty is immediately null and void where non-Baxter parts are used to repair Baxter devices.Do not lay the pump face down on components or tools which could scratch or CAUTION damage the keypad. Do not lay the pump face down with door assembly open. Ensure that wires are not pinched or overstressed.

Baxter

Baxter Flogard 6301 Service Manual Pdf

CAUTION 07-19-B1-688 FLO-GARD 6201 VOLUMETRIC INFUSION PUMP SERVICE MANUAL.Baxter’s sole obligation shall be limited to repair or replacement, at Baxter’s option and expense, of the defective part or unit, excluding batteries, for a period of one year following the date of initial delivery.Call 1-(800) -THE-PUMP for service and repair information for all instruments. Shipping costs for all units returned to Baxter shall be paid by the customer. The unit must be packed in its original container or in another Baxter approved container that provides adequate protection during shipment.